Designed for a wide range of applications, these units are ideal for hotels and motels, office buildings, schools and apartments.
|
Power Connection Kits for 5800 Series
Power Connection Kits are REQUIRED on Premium Zoneline Chassis (see chart below). The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent connection kit would be used. 265/277-volt cord set units must be installed in compliance with National Electrical Code®.
|
RAK3153/3203 230/208 volt line cord connection kit
|
RAK3303 230/208 volt line cord
connection kit
|
|
|
Related Links
|
| 230/208 Volt |
Line Cord Connected Units |
| Power Connection Kit |
RAK3153 |
RAK3203 |
RAK3303 |
| Heater KW |
2.55/2.09 |
3.45/2.82 |
5.00/4.09 |
| Watts |
2,550/2,090 |
3,450/2,820 |
5,000/4,090 |
| BTUH |
8,600/7,100 |
11,700/9,600 |
17,000/13,900 |
| Amps |
11.1/10.0 |
15.0/13.6 |
21.7/19.7 |
| Min. Circuit Amps |
15 |
20 |
30 |
| Recommended Protective Device |
15 Amp Time Delay Fuse or Breaker |
20 Amp Time Delay Fuse or Breaker |
30 Amp Time Delay Fuse or Breaker |
| 265 Volt |
Permanent Connected Units* (Cord Set) |
| Power Connection Kit |
RAK5172 |
RAK5202 |
RAK5302 |
| Heater KW |
2.55 |
3.45 |
5.0 |
| Watts |
2,560 |
3,450 |
5,000 |
| BTUH |
8,600 |
11,700 |
17,000 |
| Amps |
9.6 |
13.0 |
18.9 |
| Min. Circuit Amps |
15 |
20 |
30 |
| Recommended Protective Device |
15 Amp Time Delay Fuse or Breaker |
20 Amp Time Delay Fuse or Breaker |
30 Amp Time Delay Fuse or Breaker |
*To be used with sub-base
|