Installation - Packaged Terminal Air Conditioners

Designed for a wide range of applications, these units are ideal for hotels and motels, office buildings, schools and apartments.

Power Connection Kits for 5800 Series

Power Connection Kits are REQUIRED on Premium Zoneline Chassis (see chart below). The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent connection kit would be used. 265/277-volt cord set units must be installed in compliance with National Electrical Code®.

RAK3153/3203
RAK3153/3203
230/208 volt line cord connection kit
RAK3303
RAK3303
230/208 volt line cord connection kit

Related Links

230/208 Volt Line Cord Connected Units
Power Connection Kit RAK3153 RAK3203 RAK3303
Heater KW 2.55/2.09 3.45/2.82 5.00/4.09
Watts 2,550/2,090 3,450/2,820 5,000/4,090
BTUH 8,600/7,100 11,700/9,600 17,000/13,900
Amps 11.1/10.0 15.0/13.6 21.7/19.7
Min. Circuit Amps 15 20 30
Recommended Protective Device 15 Amp Time Delay Fuse or Breaker 20 Amp Time Delay Fuse or Breaker 30 Amp Time Delay Fuse or Breaker
265 Volt Permanent Connected Units* (Cord Set)
Power Connection Kit RAK5172 RAK5202 RAK5302
Heater KW 2.55 3.45 5.0
Watts 2,560 3,450 5,000
BTUH 8,600 11,700 17,000
Amps 9.6 13.0 18.9
Min. Circuit Amps 15 20 30
Recommended Protective Device 15 Amp Time Delay Fuse or Breaker 20 Amp Time Delay Fuse or Breaker 30 Amp Time Delay Fuse or Breaker

*To be used with sub-base