Zoneline Vertical units give home-like appearance to hotels, motels, apartments, office buildings and more!
|
Power Connection Kits for 8500 Series
The ZVAC units have a universal heater assembly that is capable of producing electric resistance heat that can operate on a 15-amp, 20-amp, or 30-amp circuit. The amount of resistance heat is determined by the selection of the correct power connection kit. This is the same type of connection used by GE for years in the Premium and Deluxe series of the Zoneline units.
Units installed on 230 or 208-volt circuits may be line cord connected by plugging the line cord into a wall-mounted receptacle in the enclosure closet or directly connected. All ZVAC units come with a unit mounted junction box to contain the wiring connections if a direct connection installation is required. The same power connection kit is used for line cord connection or to make a direct connection. Instructions for making a direct connection on 230 or 208-volt circuits are included in the unit installation instructions.
Units installed on a 265-volt circuit must be direct connectedin accordance with National Electrical Code. All ZVAC units come with a unit mounted junction box to contain the wiring connections when direct connection installation is made.

RAK3152/3202/3302 230/208 volt cord connection kit
|
|
Related Links
|
| 230/208 Volt |
Line Cord Connected Units |
| Power Connection Kit |
RAK3152 |
RAK3202 |
RAK3302 |
| Heater KW |
2.55/2.09 |
3.45/2.82 |
5.00/4.09 |
| Heater Amps |
11.1/10.0 |
15.0/13.6 |
21.7/19.7 |
| Minimum Circuit Amps |
15 |
20 |
30 |
| Recommended Protective Device |
15 Amp Time Delay Fuse or Breaker |
20 Amp Time Delay Fuse or Breaker |
30 Amp Time Delay Fuse or Breaker |
| 230/208 Volt |
Direct Connected Units |
| Power Connection Kit |
RAK4157 |
RAK4207 |
RAK4307 |
| Heater KW |
2.55/2.09 |
3.45/2.82 |
5.0/4.09 |
| Heater Amps |
11.0/10.0 |
15.0/13.6 |
21.7/19.7 |
| Minimum Circuit Amps |
15 |
20 |
30 |
| Recommended Protective Device |
15 Amp Time Delay Fuse or Breaker |
20 Amp Time Delay Fuse or Breaker |
30 Amp Time Delay Fuse or Breaker |
| 265/277 Volt |
Direct Connected Units |
| Power Connection Kit |
RAK5157 |
RAK5207 |
RAK5307 |
| Heater KW |
2.55 |
3.452 |
5.0 |
| Heater Amps |
9.7 |
13.1 |
18.9 |
| Minimum Circuit Amps |
15 |
20 |
30 |
| Recommended Protective Device |
15 Amp Time Delay Fuse or Breaker |
20 Amp Time Delay Fuse or Breaker |
30 Amp Time Delay Fuse or Breaker |
See the Architects & Engineers Design Data Manual for additional installation information.
|